• The specialist in (C)EDI applications
  • Innovative system design
  • Worldwide 24/7/365 technical support
Select Page

Ionpure MX EDI modules

The Ionpure® MX Series modules are designed with proven continuous electrodeionization (CEDI) technology. Performance on these modules has been optimized to produce high purity water for laboratory and smaller scale applications. A wide nominal flow range from 30 – 500 litres per hour increases the applicability for single module installations.

Features

  • Generates mixed-bed quality deionized water without the use of chemicals
  • Significantly lower operating costs, than conventional ion exchange
  • No need for acid/caustic, neutralization system or exchangeable DI tanks
  • Double O-ring seal guarantees leak-free operation
  • Continuous production with consistent quality
  • Concentrate recirculation and brine injection not required
  • Continuous operation

Quality Assurance

  • Firstly, CE marked.
  • Secondly, each module had a factory test to meet strict industry standards.
  • Thirdly, manufactured in an ISO 9001 and ISO 14000 quality and environmental management system.

Options

  • Power supplies
  • Power controllers
  • Earth plugs
  • Connectors
  • Systems

Applications

  • Laboratory / Pharmaceutica
  • HPI/CPI
  • Food and Beverage
  • General Industry Electro Separation
  • Semiconductor and Electronics Industry

Specifications

Specifications MX030 MX060 MX125 MX250 MX500
Shipping weight 5,4 kg
Length 184 213 274 393 629 mm
Diameter 178 178 178 178 178 mm
Minimum flowrate 15 30 62,5 125 250 m3/h
Nominal flowrate 30 60 125 250 500 m3/h
Maximum flowrate 45 90 187,5 375 750 m3/h
Maximum Voltage 200 200 200 400 600 VDC
Typical Performance
Product Quality
Product Resistivity >16 MOhm.cm*
Silica (SiO2) Removal 90 – 99 %
Depending on feed water conditions
* Actual performance may be determined on projection from DeionX.
Operating Parameters
Recovery 90 – 95 %
Feed Pressure 1,4 – 5 bar
DC Amperage 0 – 2,5 Amp
Pressure Drop Range at Nominal Flow 0,7 – 1,4 bar
Maximum Feedwater Specifications
Feed water conductivity equivalent, including CO2 and Silica < 40 µS/cm
Feed water source RO permeate
Temperature min to max 5 to 45 ⁰C
Inlet pressure 1,4 – 7 bar
Maximum Free chlorine (as CI) < 0,02 ppm
Iron (as Fe) < 0,01 ppm
Manganese (as Mn) < 0,01 ppm
Sulfide (S-) < 0,01 ppm
PH 4 – 11
Total hardness (as CaCO3) < 1,0 ppm
Dissolved organics (TOC as C) < 0,5 ppm
Silica (SiO2) < 1,0 ppm
Deionx
Select Page