Ionpure LX EDI modules
Deionx is known as an Ionpure LX, VNX and MX and EDI supplier and specialist in the Netherlands. We have several Ionpure LX EDI modules like the LX-Z, LX-X and LX-HI. Which system is best suited for you, depends on the needs and nature of your company. Please contact Deionx and tell us your needs. In return, as a supplier and specialist, we can offer you a tailor-made solution.
Ionpure LX EDI
LX-Z
The Ionpure® LX-Z industrial modules firstly generates high purity water through electrodeionization and secondly, are specifically designed for industrial applications. Ionpure modules consistently deliver maximum reliability and certainly, superior performance for power, HPI/CPI and general electronics without regeneration downtime.
LX-X
The Ionpure® LX-X industrial modules produce high purity water through electrodeionization for a wide range of industrial applications. LX-X modules consistently deliver maximum reliability and superior performance for power, HPI/CPI, general electronics, food and beverage and laboratory applications without regeneration downtime.
LX-HI
Hot water sanitization is more effective than chemical sanitization for controlling microbial growth. Ease of operation, maximum reliability and low operating costs are signature features of Ionpure® modules. LX-HI modules are ideal for firstly, pharmaceutical, secondly, biotechnology and thirdly, other applications where they desire chemical-free, instant hot water sanitization. LX-HI modules produce high-purity water without regeneration downtime.
Options
LX-Z
- Power supplies
- Power controllers
- Power Cables
- Earth plugs
- Connectors
LX-X
- Power supplies
- Power controllers
- Power Cables
- Earth plugs
- Connectors
LX-HI
- Power supplies
- Power controllers
- Power Cables
- Earth plugs
- Connectors
Applications
LX-Z
- Power Generation (NOx, Boiler Feed)
- HPI/CPI
- Food and Beverage
- General Industry Electro Separation
- Semiconductor and Electronics Industry
LX-X
- Power Generation (NOx, Boiler Feed)
- HPI/CPI
- Food and Beverage
- General Industry Electro Separation
- Semiconductor and Electronics Industry
LX-HI
- Pharmaceutical
- Laboratory Semiconductor
- HPI/CPI
Specifications
LX-Z
Specifications | LXM04Z | LXM10Z | LXM18Z | LXM24Z | LXM30Z | LXM45Z | |
---|---|---|---|---|---|---|---|
Shipping weight | 68 | 91 | 100 | 113 | 123 | 145 | kg |
Operating weight | 50 | 68 | 77 | 91 | 100 | 122,5 | kg |
Height | 606 | 606 | 606 | 606 | 606 | 606 | mm |
Wide | 318 | 318 | 318 | 318 | 318 | 318 | mm |
Depth | 257 | 348 | 488 | 602 | 697 | 907 | mm |
Minimum flowrate | 0,22 | 0,55 | 1,1 | 1,4 | 1,65 | 2,55 | m3/h |
Nominal flowrate | 0,44 | 1,1 | 2,0 | 2,8 | 3,3 | 5,1 | m3/h |
Maximum flowrate | 0,67 | 1,65 | 3,1 | 4,2 | 5,11 | 7,67 | m3/h |
Maximum Voltage | 53 | 133 | 240 | 320 | 400 | 600 | VDC |
Typical Performance | |
---|---|
Product Quality | |
Product Resistivity @ min flow @ nom flow @ max flow |
>17 MOhm.cm** > 15 MOhm.cm** > 7 MOhm.cm** |
Silica (SiO2) Removal | 90 – 99 % Depending on feed water conditions |
* Actual performance may be determined on projection from DeionX. **Performance based on maximum Feed Water Conductivity Equivalent (40 µS/cm) |
|
Operating Parameters | |
Recovery | 90 – 95 % |
Maximum Feed Pressure | 7 bar |
DC Amperage | 0 – 6 Amp |
Pressure Drop Range at Nominal Flow | 1,4 – 2,1 bar |
Maximum Feedwater Specifications | |
---|---|
Feed water conductivity equivalent, including CO2 and Silica | < 40 µS/cm |
Feed water source | RO permeate |
Inlet pressure | 1,4 – 7 bar |
Maximum Free chlorine (as CI) | < 0,02 ppm |
Iron (as Fe) | < 0,01 ppm |
Manganese (as Mn) | < 0,01 ppm |
Sulfide (S-) | < 0,01 ppm |
PH | 4 – 11 |
Total hardness (as CaCO3) | < 1,0 ppm |
Dissolved organics (TOC as C) | < 0,5 ppm |
Silica (SiO2) | < 1,0 ppm |
LX-X
Specifications | LXM04X | LXM10X | LXM18X | LXM24X | LXM30X | LXM45X | |
---|---|---|---|---|---|---|---|
Shipping weight | 68 | 91 | 100 | 113 | 123 | 145 | kg |
Operating weight | 50 | 68 | 77 | 91 | 100 | 122,5 | kg |
Height | 606 | 606 | 606 | 606 | 606 | 606 | mm |
Wide | 318 | 318 | 318 | 318 | 318 | 318 | mm |
Depth | 257 | 348 | 488 | 602 | 697 | 907 | mm |
Minimum flowrate | 0,22 | 0,55 | 1,1 | 1,4 | 1,65 | 2,55 | m3/h |
Nominal flowrate | 0,44 | 1,1 | 2,0 | 2,8 | 3,3 | 5,1 | m3/h |
Maximum flowrate | 0,67 | 1,65 | 3,1 | 4,2 | 5,11 | 7,67 | m3/h |
Maximum Voltage | 53 | 133 | 240 | 320 | 400 | 600 | VDC |
Typical Performance | |
---|---|
Product Quality | |
Product Resistivity @ min flow @ nom flow @ max flow |
>17 MOhm.cm** > 15 MOhm.cm** > 7 MOhm.cm** |
Silica (SiO2) Removal | 90 – 99 % Depending on feed water conditions |
* Actual performance may be determined on projection from DeionX. **Performance based on maximum Feed Water Conductivity Equivalent (40 µS/cm) |
|
Operating Parameters | |
Recovery | 90 – 95 % |
Maximum Feed Pressure | 7 bar |
DC Amperage | 0 – 6 Amp |
Pressure Drop Range at Nominal Flow | 1,4 – 2,1 bar |
Temperature min to max5 to 45 ⁰C
Maximum Feedwater Specifications | |
---|---|
Feed water conductivity equivalent, including CO2 and Silica | < 40 µS/cm |
Feed water source | RO permeate |
Inlet pressure | 1,4 – 7 bar |
Maximum Free chlorine (as CI) | < 0,02 ppm |
Iron (as Fe) | < 0,01 ppm |
Manganese (as Mn) | < 0,01 ppm |
Sulfide (S-) | < 0,01 ppm |
PH | 4 – 11 |
Total hardness (as CaCO3) | < 1,0 ppm |
Dissolved organics (TOC as C) | < 0,5 ppm |
Silica (SiO2) | < 1,0 ppm |
LX-HI
Specifications | LXM04HI | LXM10HI | LXM18HI | LXM24HI | LXM30HI | LXM45HI | |
---|---|---|---|---|---|---|---|
Shipping weight | 68 | 91 | 100 | 113 | 123 | 145 | kg |
Operating weight | 50 | 68 | 77 | 91 | 100 | 122,5 | kg |
Height | 606 | 606 | 606 | 606 | 606 | 606 | mm |
Wide | 318 | 318 | 318 | 318 | 318 | 318 | mm |
Depth | 257 | 348 | 488 | 602 | 697 | 907 | mm |
Minimum flowrate | 0,22 | 0,55 | 1,1 | 1,4 | 1,65 | 2,55 | m3/h |
Nominal flowrate | 0,44 | 1,1 | 2,0 | 2,8 | 3,3 | 5,1 | m3/h |
Maximum flowrate | 0,67 | 1,65 | 3,1 | 4,2 | 5,11 | 7,67 | m3/h |
Maximum Voltage | 53 | 133 | 240 | 320 | 400 | 600 | VDC |
Typical Performance | |
---|---|
Product Quality | |
Product Resistivity @ min flow @ nom flow @ max flow |
>17 MOhm.cm** > 15 MOhm.cm** > 7 MOhm.cm** |
Silica (SiO2) Removal | 90 – 99 % Depending on feed water conditions |
* Actual performance may be determined on projection from DeionX. **Performance based on maximum Feed Water Conductivity Equivalent (40 µS/cm) |
|
Operating Parameters | |
Recovery | 90 – 95 % |
Maximum Feed Pressure | 7 bar |
DC Amperage | 0 – 10 Amp |
Pressure Drop Range at Nominal Flow | 1,4 – 2,1 bar |
Maximum Feedwater Specifications | |
---|---|
Feed water conductivity equivalent, including CO2 and Silica | < 40 µS/cm |
Feed water source | RO permeate |
Inlet pressure | 1,4 – 7 bar |
Maximum Free chlorine (as CI) | < 0,02 ppm |
Iron (as Fe) | < 0,01 ppm |
Manganese (as Mn) | < 0,01 ppm |
Sulfide (S-) | < 0,01 ppm |
PH | 4 – 11 |
Total hardness (as CaCO3) | < 1,0 ppm |
Dissolved organics (TOC as C) | < 0,5 ppm |
Silica (SiO2) | < 1,0 ppm |
Downloads
LX-Z
- Ionpure-IP-LXM30Z-4-W3T17312
- Ionpure-IP-LXM45Z-4-W3T17314
- Ionpure-IP-LXM04Z-4-W3T17286
- Ionpure-IP-LXM10Z-4-W3T17291
- Ionpure-IP-LXM18Z-4-W3T17297
- Ionpure-IP-LXM24Z-4-W3T17303
LX-X
- Ionpure-IP-LXM18X-4-W3T17295
- Ionpure-IP-LXM10X-4-W3T17289
- Ionpure-IP-LXM04X-4-W3T17318
- Ionpure-IP-LXM45X-4-W3T187073
- Ionpure-IP-LXM30X-4-W3T17309